{"id":17116,"date":"2023-06-30T11:39:01","date_gmt":"2023-06-30T07:39:01","guid":{"rendered":"https:\/\/globecore.info\/?p=17116"},"modified":"2024-03-19T18:55:39","modified_gmt":"2024-03-19T14:55:39","slug":"transformer-yagi-tan-delta-testi","status":"publish","type":"post","link":"https:\/\/globecore.info\/az\/transformer-yagi-tan-delta-testi\/","title":{"rendered":"Transformer ya\u011f\u0131 tan delta testi"},"content":{"rendered":"<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131 g\u00fcc transformatorlar\u0131n\u0131n i\u015find\u0259 m\u00fch\u00fcm elementdir. Soyutma, izolyasiya v\u0259 g\u0259rginlik izolyasiyas\u0131 da daxil olmaqla bir \u00e7ox rol oynay\u0131r. Transformator ya\u011f\u0131, transformatorda h\u0259r hans\u0131 elektrik nasazl\u0131\u011f\u0131n\u0131n qar\u015f\u0131s\u0131n\u0131 almaq \u00fc\u00e7\u00fcn izolyator kimi xidm\u0259t edir. Buna g\u00f6r\u0259 transformator mayesinin keyfiyy\u0259tini m\u00fcnt\u0259z\u0259m olaraq qiym\u0259tl\u0259ndirm\u0259k \u00e7ox vacibdir. Transformator <\/span><b>ya\u011f tan delta testi<\/b><span style=\"font-weight: 400;\"> mayenin keyfiyy\u0259tinin \u0259sas g\u00f6st\u0259ricisidir. Bu m\u0259qal\u0259 neftin dielektrik dissipasiyas\u0131 m\u00fcayin\u0259sinin \u0259h\u0259miyy\u0259tini, onun \u00fcst\u00fcnl\u00fckl\u0259rini v\u0259 testin apar\u0131lmas\u0131 \u00fcsullar\u0131n\u0131 ara\u015fd\u0131r\u0131r.<\/span><\/p>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131n\u0131n dielektrik g\u00fcc\u00fc n\u0259dir?<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131n\u0131n izolyasiya qabiliyy\u0259ti g\u0259rginlik alt\u0131nda elektrik c\u0259r\u0259yan\u0131n\u0131n pozulmas\u0131na m\u00fcqavim\u0259t g\u00f6st\u0259rm\u0259k qabiliyy\u0259ti il\u0259 \u00f6l\u00e7\u00fcl\u00fcr. Transformator ya\u011f\u0131n\u0131n izolyasiya qabiliyy\u0259ti vacibdir, \u00e7\u00fcnki bu, transformatorun keyfiyy\u0259tini v\u0259 i\u015fini g\u00f6st\u0259rir. Bu tutum, mayenin tutumunun vakuumun tutumuna nisb\u0259tini t\u0259msil ed\u0259n ya\u011f\u0131n dielektrik sabitinin hesablanmas\u0131 il\u0259 qiym\u0259tl\u0259ndirilir.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131n\u0131n izolyasiya qabiliyy\u0259tin\u0259 onun kimy\u0259vi t\u0259rkibi, \u00e7irkl\u0259ndiricil\u0259r, r\u00fctub\u0259t v\u0259 temperatur kimi bir s\u0131ra amill\u0259r t\u0259sir ed\u0259 bil\u0259r. N\u0259mlik transformator ya\u011f\u0131n\u0131n izolyasiya qabiliyy\u0259tini azalda bil\u0259n \u0259sas elementdir. Bel\u0259likl\u0259, izolyasiya qabiliyy\u0259tini qorumaq \u00fc\u00e7\u00fcn transformator ya\u011f\u0131n\u0131 susuz v\u0259 n\u0259msiz saxlamaq vacibdir.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Transformatorun izolyasiya qabiliyy\u0259tin\u0259 z\u0259man\u0259t verm\u0259k \u00fc\u00e7\u00fcn ard\u0131c\u0131l s\u0131naq t\u0259l\u0259b olunur. Ya\u011f tan delta testi transformator ya\u011f\u0131n\u0131n keyfiyy\u0259tini qiym\u0259tl\u0259ndirm\u0259k \u00fc\u00e7\u00fcn d\u0259qiq v\u0259 etibarl\u0131 \u00fcsuldur. Test transformator mayesinin dielektrik itki buca\u011f\u0131n\u0131n tangensini qiym\u0259tl\u0259ndirir, bu, mayenin elektrik enerjisini udmaq v\u0259 yaymaq potensial\u0131n\u0131 t\u0259yin ed\u0259n m\u00fch\u00fcm parametrdir.<\/span><\/p>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Dielektrik g\u00fcc\u00fcn\u00fc nec\u0259 yoxlamaq olar?<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131n\u0131n izolyasiya qabiliyy\u0259tini qiym\u0259tl\u0259ndirm\u0259k \u00fc\u00e7\u00fcn geni\u015f istifad\u0259 olunan bir texnikad\u0131r <\/span><b>ya\u011f tan delta testi.<\/b><span style=\"font-weight: 400;\"> Bu test ya\u011f\u0131n dielektrik itki buca\u011f\u0131n\u0131n tangensini qiym\u0259tl\u0259ndirir, bu da mayenin elektrik enerjisini udmaq v\u0259 yaymaq qabiliyy\u0259tini g\u00f6st\u0259rir. Test iki elektrod aras\u0131nda ya\u011fa alternativ c\u0259r\u0259yan g\u0259rginliyi t\u0259tbiq etm\u0259kl\u0259 v\u0259 ya\u011f daxilind\u0259 g\u0259rginlik v\u0259 c\u0259r\u0259yan aras\u0131ndak\u0131 faza buca\u011f\u0131n\u0131 t\u0259yin etm\u0259kl\u0259 h\u0259yata ke\u00e7irilir.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>Ya\u011f tan delta testi<\/b><span style=\"font-weight: 400;\"> transformator ya\u011f\u0131n\u0131n v\u0259ziyy\u0259tini t\u0259yin etm\u0259k \u00fc\u00e7\u00fcn etibarl\u0131 v\u0259 d\u0259qiq \u00fcsuldur. O, mayenin izolyasiya qabiliyy\u0259tini z\u0259ifl\u0259d\u0259 bil\u0259n n\u0259m kimi \u00e7irkl\u0259ndiricil\u0259ri a\u015fkar edir. Bundan \u0259lav\u0259, o, mayenin y\u00fcks\u0259k temperaturlara, oksigen\u0259 v\u0259 dig\u0259r \u00e7irkl\u0259r\u0259 m\u0259ruz qalmas\u0131 n\u0259tic\u0259sind\u0259 yaranan deqradasiya \u0259lav\u0259 m\u0259hsullar\u0131n\u0131 m\u00fc\u0259yy\u0259n edir. Test n\u0259tic\u0259l\u0259ri ad\u0259t\u0259n dielektrik itki buca\u011f\u0131n\u0131n tangensi v\u0259 ya tan deltas\u0131, \u00f6l\u00e7\u00fcs\u00fcz bir d\u0259y\u0259r kimi ifad\u0259 edilir. A\u015fa\u011f\u0131 tan delta \u0259la izolyasiya x\u00fcsusiyy\u0259tl\u0259rini, y\u00fcks\u0259k d\u0259y\u0259r is\u0259 z\u0259if izolyasiyan\u0131 g\u00f6st\u0259rir.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">h\u0259yata ke\u00e7irm\u0259k vacibdir <\/span><b>ya\u011f tan delta testi<\/b><span style=\"font-weight: 400;\"> ASTM D924 v\u0259 ya IEC 60247 kimi m\u00fc\u0259yy\u0259n edilmi\u015f s\u0259naye standartlar\u0131na \u0259m\u0259l edin. Bu standartlar d\u0259qiq v\u0259 etibarl\u0131 s\u0131naq n\u0259tic\u0259l\u0259rini t\u0259min etm\u0259k \u00fc\u00e7\u00fcn s\u0131naq avadanl\u0131qlar\u0131n\u0131, \u015f\u0259rtl\u0259ri v\u0259 prosedurlar\u0131 dikt\u0259 edir. X\u00fclas\u0259, ya\u011f tan delta m\u00fcayin\u0259si transformator ya\u011f\u0131n\u0131n v\u0259ziyy\u0259tini qiym\u0259tl\u0259ndirm\u0259k v\u0259 g\u00fcc transformatorlar\u0131n\u0131n etibarl\u0131 i\u015fl\u0259m\u0259sini t\u0259min etm\u0259k \u00fc\u00e7\u00fcn kritik diaqnostik al\u0259tdir.<\/span><\/p>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131n\u0131n dielektrik itki buca\u011f\u0131n\u0131n tangensi (tanq deltas\u0131)<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Transformator ya\u011f\u0131nda dielektrik itki buca\u011f\u0131n\u0131n tangensi t\u0259tbiq olunan g\u0259rginliyin tezliyind\u0259n t\u0259sirl\u0259nir. Y\u00fcks\u0259k tezlikl\u0259r daha y\u00fcks\u0259k tan delta r\u0259q\u0259ml\u0259ri ver\u0259 bil\u0259r ki, bu da izolyasiya x\u00fcsusiyy\u0259tl\u0259rini azald\u0131r. Bel\u0259likl\u0259, d\u0259qiq n\u0259tic\u0259l\u0259r \u00fc\u00e7\u00fcn m\u00fcvafiq tezlikd\u0259 tan deltas\u0131n\u0131n qiym\u0259tl\u0259ndirilm\u0259sinin apar\u0131lmas\u0131 \u00e7ox vacibdir. H\u0259m d\u0259 diqq\u0259t\u0259layiqdir ki, tan delta d\u0259y\u0259rl\u0259ri transformatorda istifad\u0259 olunan mayenin n\u00f6v\u00fcnd\u0259n as\u0131l\u0131 olaraq d\u0259yi\u015f\u0259 bil\u0259r. M\u0259s\u0259l\u0259n, t\u0259bii esterd\u0259n \u0259ld\u0259 edil\u0259n ya\u011f, adi mineral \u0259sasl\u0131 ya\u011flarla m\u00fcqayis\u0259d\u0259 \u00fcmumiyy\u0259tl\u0259 daha a\u015fa\u011f\u0131 tan delta d\u0259y\u0259rl\u0259ri n\u00fcmayi\u015f etdirir. Bu f\u0259rq t\u0259bii ester ya\u011flar\u0131n\u0131n f\u0259rqli kimy\u0259vi t\u0259rkibin\u0259 g\u00f6r\u0259 yaran\u0131r v\u0259 onlar\u0131 elektrik g\u0259rginliyin\u0259 daha davaml\u0131 edir.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-17119\" src=\"https:\/\/globecore.info\/wp-content\/uploads\/2023\/06\/tor-3-3-2.jpg\" alt=\"transformator ya\u011f\u0131 tan delta testi\" width=\"350\" height=\"467\" srcset=\"https:\/\/globecore.info\/wp-content\/uploads\/2023\/06\/tor-3-3-2.jpg 576w, https:\/\/globecore.info\/wp-content\/uploads\/2023\/06\/tor-3-3-2-225x300.jpg 225w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><\/p>\n<h2 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Ya\u011f\u0131n dielektrik itkisini yoxlayan cihaz: Transformator ya\u011f\u0131n\u0131n dielektrik itki buca\u011f\u0131n\u0131n tangensini t\u0259yin etm\u0259k \u00fc\u00e7\u00fcn cihaz TOR-3 GlobeCore<\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">TOR-3 <\/span><b><i>GlobeCore<\/i><\/b><span style=\"font-weight: 400;\"> dielektrik itki buca\u011f\u0131n\u0131n tangensini qiym\u0259tl\u0259ndir\u0259r\u0259k transformator ya\u011f\u0131nda dielektrik itkisini qiym\u0259tl\u0259ndirm\u0259k \u00fc\u00e7\u00fcn n\u0259z\u0259rd\u0259 tutulmu\u015f cihazd\u0131r. O, tan delta d\u0259y\u0259rini t\u0259qdim ed\u0259r\u0259k, ya\u011fdak\u0131 g\u0259rginlik v\u0259 c\u0259r\u0259yan aras\u0131ndak\u0131 faza buca\u011f\u0131n\u0131 hesablay\u0131r. TOR-3-d\u0259n istifad\u0259 transformator ya\u011f\u0131n\u0131n keyfiyy\u0259tinin d\u0259qiq v\u0259 etibarl\u0131 qiym\u0259tl\u0259ndirilm\u0259sini t\u0259min edir.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Ya\u011f Dielektrik \u0130tki Test Cihaz\u0131, qura\u015fd\u0131rma menyusunda \u0259ld\u0259 edil\u0259 bil\u0259n \u0259vv\u0259lc\u0259d\u0259n m\u00fc\u0259yy\u0259n edilmi\u015f standartlara v\u0259 istifad\u0259\u00e7i t\u0259r\u0259find\u0259n m\u00fc\u0259yy\u0259n edilmi\u015f prosedurlara uy\u011fun olaraq s\u0131naqlar\u0131n apar\u0131lmas\u0131na imkan ver\u0259n tam avtomatik aparatd\u0131r.<\/span><\/p>\n<h3 style=\"text-align: center;\"><span style=\"font-weight: 400;\">Ya\u011f Dielektrik Test Cihaz\u0131n\u0131n (TOR-3) istifad\u0259sinin \u00fcst\u00fcnl\u00fckl\u0259ri v\u0259 \u00fcst\u00fcnl\u00fckl\u0259ri<\/span><\/h3>\n<p style=\"text-align: justify;\"><a href=\"https:\/\/globecore.info\/az\/products\/pribory\/pribor-dlya-izmereniya-tangensa-ugla-dielektricheskih-poter-i-dielektricheskoj-pronitsaemosti-zhidkih-dielektrikov\/\"><span style=\"font-weight: 400;\">TOR-3 <\/span><b><i>GlobeCore<\/i><\/b><\/a><span style=\"font-weight: 400;\"> Ya\u011f dielektrik test cihaz\u0131 bir s\u0131ra \u00fcst\u00fcnl\u00fckl\u0259r v\u0259 \u00fcst\u00fcnl\u00fckl\u0259r t\u0259klif edir, m\u0259s\u0259l\u0259n:<\/span><\/p>\n<ol style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">d\u0259qiqliyi qoruyark\u0259n s\u00fcr\u0259tli \u00f6l\u00e7m\u0259l\u0259r;<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">n\u0259tic\u0259l\u0259rin saxlanmas\u0131na v\u0259 \u00e7ap\u0131na imkan ver\u0259n komp\u00fcter t\u0259r\u0259find\u0259n idar\u0259 olunan avtomatla\u015fd\u0131r\u0131lm\u0131\u015f \u00f6l\u00e7m\u0259 prosesl\u0259ri;<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">qrafik v\u0259 ya r\u0259q\u0259msal formatlarda onlayn n\u0259tic\u0259l\u0259r\u0259 baxmaq v\u0259 arxivl\u0259\u015fdirm\u0259y\u0259 imkan ver\u0259n \u201cTangent Service\u201d m\u00fch\u0259ndis proqram\u0131 il\u0259 uy\u011funluq;<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">t\u0259dqiqat proqramlar\u0131 \u00fc\u00e7\u00fcn t\u0259nziml\u0259n\u0259n parametrl\u0259r;<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">y\u00fcng\u00fcl, y\u0131\u011fcam v\u0259 istifad\u0259\u00e7i dostu dizayn.<\/span><\/li>\n<\/ol>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">X\u00fclas\u0259, transformator ya\u011f\u0131 g\u00fcc transformatorlar\u0131n\u0131n i\u015find\u0259 m\u00fch\u00fcm rol oynay\u0131r. Buna g\u00f6r\u0259 d\u0259, bu ya\u011f\u0131n keyfiyy\u0259tini m\u00fcnt\u0259z\u0259m olaraq qiym\u0259tl\u0259ndirm\u0259k \u00e7ox vacibdir. <\/span><b>Ya\u011f tan delta testi<\/b><span style=\"font-weight: 400;\"> transformator ya\u011f\u0131n\u0131n keyfiyy\u0259tini qiym\u0259tl\u0259ndirm\u0259k \u00fc\u00e7\u00fcn etibarl\u0131 v\u0259 d\u0259qiq bir vasit\u0259 kimi xidm\u0259t edir. Dielektrik itki buca\u011f\u0131n\u0131n tangensi ya\u011f\u0131n elektrik enerjisini udmaq v\u0259 buraxmaq qabiliyy\u0259tini \u00f6l\u00e7\u0259n kritik bir parametrdir. Ya\u011f dielektrik test cihaz\u0131 TOR-3 <\/span><b><i>GlobeCore<\/i><\/b><span style=\"font-weight: 400;\"> transformator ya\u011f\u0131n\u0131n keyfiyy\u0259tini yoxlamaq \u00fc\u00e7\u00fcn effektiv v\u0259 d\u0259qiq yana\u015fmad\u0131r. Ya\u011f dielektrik test cihaz\u0131n\u0131n istifad\u0259si \u00e7oxsayl\u0131 \u00fcst\u00fcnl\u00fckl\u0259r v\u0259 \u00fcst\u00fcnl\u00fckl\u0259r t\u0259min edir v\u0259 onu transformator ya\u011f\u0131n\u0131n s\u0131naqdan ke\u00e7irilm\u0259si \u00fc\u00e7\u00fcn q\u0259na\u0259tli h\u0259ll edir.<\/span><\/p>\n<p style=\"text-align: justify;\">\n","protected":false},"excerpt":{"rendered":"<p>Transformator ya\u011f\u0131 g\u00fcc transformatorlar\u0131n\u0131n i\u015find\u0259 m\u00fch\u00fcm elementdir. Soyutma, izolyasiya v\u0259 g\u0259rginlik izolyasiyas\u0131 da daxil olmaqla bir \u00e7ox rol oynay\u0131r. Transformator ya\u011f\u0131, transformatorda h\u0259r hans\u0131 elektrik nasazl\u0131\u011f\u0131n\u0131n qar\u015f\u0131s\u0131n\u0131 almaq \u00fc\u00e7\u00fcn izolyator kimi xidm\u0259t edir. Buna g\u00f6r\u0259 transformator mayesinin keyfiyy\u0259tini m\u00fcnt\u0259z\u0259m olaraq qiym\u0259tl\u0259ndirm\u0259k \u00e7ox vacibdir. Transformator ya\u011f tan delta testi mayenin keyfiyy\u0259tinin \u0259sas g\u00f6st\u0259ricisidir. Bu m\u0259qal\u0259 neftin<a class=\"cg-read-more\" href=\"https:\/\/globecore.info\/az\/transformer-yagi-tan-delta-testi\/\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":4,"featured_media":17117,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[3036,3037],"tags":[],"class_list":["post-17116","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mqallr","category-stati-az"],"acf":[],"language":"az","_links":{"self":[{"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/posts\/17116","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/comments?post=17116"}],"version-history":[{"count":2,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/posts\/17116\/revisions"}],"predecessor-version":[{"id":17122,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/posts\/17116\/revisions\/17122"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/media\/17117"}],"wp:attachment":[{"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/media?parent=17116"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/categories?post=17116"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/globecore.info\/az\/wp-json\/wp\/v2\/tags?post=17116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}